Multi-channel input

The MV1000 can support up to 24 channels (2 times as many channels as before), while the MV2000 can support up to 48 (1.6 times as many channels as before)! Naturally, every channel is isolated, and you can count on reliable data acquisition!

Multi-channel input

By connecting to the DAQMASTER Series MW100, you can increase channel input by a maximum of 300 channels. Connection is as easy as the touch of a button!

Multi-channel input


High-speed sampling

By measuring in high-speed mode, you can attain a minimum measurement interval of 25 ms for every channel (MV1004, MV1008, and MV2008). With a measurement interval that is 5 times faster than before, you can acquire more detailed data.

High-speed sampling

High-capacity memory

Equipped with up to 200 MB (170 times more memory than before) of internal flash memory! By backing up with external media (CF card), you can further ensure the safety of your data! If a power outage should occur, then the unit will automatically resume measurement when power returns.


Acquire the data you need with a variety of measuring modes

The MV1000 and MV2000 are loaded with a variety of measurement features. By matching these features to your measurement goals, you are sure to be able to collect the data you need.

●Free mode
Data acquisition is user prompted, and acquisition of the data sequence occurs at the set sampling rate.

●Trigger modes
You can use a variety of triggers—such as alarm, external contact, time, and calculated data—to set the timing of data acquisition. By combining these with pre-trigger functions and other features, you can efficiently acquire the data you need.







forinquiries

Wide range of input types

Accepts thermocouple (up to 18 types), RTD (up to 12 types), DC voltage (within ± 50 V), and contact inputs.

Wide Range of Input Types
 

Isolated channel inputs

DC voltage and thermocouple inputs in all MVAdvanced models are channel-isolated. (Channel isolation for RTD inputs is optional on some models.)

isolated channel inputs

The high common mode noise characteristic enabled by isolated channel inputs ensures stable measurements in a wide range of applications.


Hardware to ensure reliability

 

● High-breakdown-voltage solid-state relays

MVAdvanced uses high-breakdown-voltage solid-state relays developed by Yokogawa as scanners for switching input signals. These relays consist of MOSFETs capable of withstanding high voltage (1500 V DC) with low leakage current (3 nA), and power-output photocouplers. They provide high-speed scanning (125 ms/48 channels in the MV2048) while increasing scanner life and eliminating noise.

High-breakdown-voltage solid-state relays

●Compliance with safety standards and EMC standards
Another indication of the reliability of MVAdvanced is their compliance with the stringent specifications for international safety and electromagnetic compatibility (EMC) standards. Of course, MVAdvanced have also been approved for the CE standards.

CSA: CSA22.2 No61010-1, installation category
II, pollution degree 2
UL: UL61010-1 (CSA NRTL/C)

CE:EMC directive: 

EN61326 compliance (Emission: Class A, Immunity: Annex A)
EN61000-3-2 compliant
EN61000-3-3 compliant
EN55011 compliant, Class A Group 1

Low voltage EN61010-1 compliant,

directive: 

measurement category II, pollution degree 2

C-Tick: AS/NZS CISPR11 compliant, Class A Group 1

Compliance with safety standards and EMC standards

Media FIFO function

This function ensures that the external medium (CF card) always retains the latest data when files are saved to it automatically.
When the CF card is full or the maximum number of files that can be saved (1000) is exceeded, the oldest files are deleted to make room for the newest files. The media FIFO function allows you to use the MV continuously for long periods of time without having to change the CF card.

Media FIFO function
     
Easy Setup Reliable Recording Easy-to-
read Display
Smart Analysis
Back (Easy Setup)   Next (Easy-to-read Display)
     