MVAdvanced
| | | | | |
| | | |
홈 퀵 투어 4개의 특징 사양 다운로드 문의

사양

문의
 
관련제품

Models

MV1000

Model code Suffix code Option code Description
MV1004     MVAdvanced MV1000 4 ch, 125 ms
(Fast sampling mode: 25 ms)
MV1006     MVAdvanced MV1000 6 ch, 1 s
(Fast sampling mode: 125 ms)
MV1008 *9     MVAdvanced MV1000 8 ch, 125 ms
(Fast sampling mode: 25 ms)
MV1012     MVAdvanced MV1000 12 ch, 1 s
(Fast sampling mode: 125 ms)
MV1024 *9     MVAdvanced MV1000 24 ch, 1 s
(Fast sampling mode: 125 ms)
Internal Memory -1   Standard Memory (80 MB)
-2   Large Memory (200 MB)
Extranal Media -4   CF card (with media) + USB
Language -2   English/German/French
-4   Korean
Input Terminal -1   Clamped terminal
-2   Screw terminal (M4)
Power Supply -1   100 VAC, 240 VAC
-2   12 VDC  *1
-3   Rechargeable battery  *1
Power Code M   Power cord PSE Standard
D   Power cord UL/CSA Standard
F   Power cord VDE Standard
R   Power cord SAA Standard
Q   Power cord BS/PSB Standard *11
H   Power cord GB Standard
P   Power cord EK Standard *10
W   without AC adapter, Power code *2
Options /A1 Alarm output 2 points *3 *9
/A2 Alarm output 4 points *3 *9
/A3 Alarm output 6 points *3 *4 *9
/C2 RS-232 interface *5
/C3 RS-422/485 interface *5
/F1 FAIL/Status output *4 *9
/M1 Mathematical functions
/N1 Cu10,Cu25 RTD input/3 leg isolated RTD
/N2 3 leg isolated RTD *6
/N3 Extended input type (PR40-20, JPt50, etc.)
/R1 Remote control *9
/TPS2 24 VDC transmitter power supply (2 loops) *7 *9
/PM1 Pulse input (including remote control and mathematical functions) *8 *9
/CC1 Calibration correction function
*1 An AC adapter is included as a standard accessory.
*2 W can be specified for only 12 VDC.
*3 /A1, /A2 and /A3 cannot be specified together.
*4 /A3 and /F1 cannot be specified together.
*5 /C2 and /C3 cannot be specified together.
*6 /N2 can be specified for only MV1006, MV1012 and MV1024.
*7 In case that /TPS2 is specified, /A2, /A3, /F1 and /PM1 cannot be specified together.
*8 In case that /PM1 is specified, /A3, /M1, /R1 and /TPS2 cannot be specified together.
   And The /A1/F1 combination cannot be specified at the same time.
*9 In case that MV1008, MV1024 is specified, /A1, /A2, /A3, /F1, /R1, /TPS2 and /PM1 cannot be specified together.
*10 "P" (EK standard) can be specified for only the 12 VDC or battery model.
*11 "Q" (PSB standard) can be specified for only the 12 VDC or battery model.
 

MV2000

Model code Suffix code Option code Description
MV2008     MVAdvanced MV2000 8 ch, 125 ms
(Fast sampling mode: 25 ms)
MV2010     MVAdvanced MV2000 10 ch, 1 s
(Fast sampling mode: 125 ms)
MV2020     MVAdvanced MV2000 20 ch, 1 s
(Fast sampling mode: 125 ms)
MV2030     MVAdvanced MV2000 30 ch, 1 s
(Fast sampling mode: 125 ms)
MV2040     MVAdvanced MV2000 40 ch, 1 s
(Fast sampling mode: 125 ms)
MV2048     MVAdvanced MV2000 48 ch, 1 s
(Fast sampling mode: 125 ms)
Internal memory
-1   Standard memory (80 MB)
-2   Large memory (200 MB)
External media -4   CF card (with media) + USB
Language -2   English/German/French
-4   Korean
Input terminal -1   Clamped terminal
-2   Screw terminal (M4)
Power supply -1   100 VAC, 240 VAC
-2   12VDC *1
Power cord M   Power cord PSE Standard
D   Power cord UL/CSA Standard
F   Power cord VDE Standard
R   Power cord SAA Standard
Q   Power cord BS/PSB Standard *11
H   Power cord GB Standard
P   Power cord EK Standard  *10
W   without AC adapter, Power code  *2
Options /A1 Alarm output 2 points  *3
/A2 Alarm output 4 points *3
/A3 Alarm output 6 points *3
/A4 Alarm output 12 points *3 *4
/C2 RS-232 interface *5
/C3 RS-422/485 interface *5
/F1 FAIL/Status output *4
/M1 Mathmatical functions
/N1 Cu10,Cu25 RTD input/3 leg isolated RTD
/N2 3 leg isolated RTD *6
/N3 Extended Input type (PR40-20, JPt50, etc.)
/R1 Remote control
/TPS4 24 VDC transmitter power supply (4 loops) *7
/PM1 Pulse input (including remote control and mathematical functions) *8
/CC1 Calibration correction function
/MC1 External input function *9
*1 An AC adapter is included as a standard accessory. 
*2 W can be specified for only 12 VDC
*3 /A1, /A2, /A3 and /A4 cannot be specified together.
*4 /A4 and /F1 cannot be specified together.
*5 /C2 and /C3 cannot be specified together.
*6 /N2 can be specified for only MV2010, MV2020, MV2030, MV2040 and MV2048.
*7 In case that /TPS4 is specified, /A4 cannot be specified together. And The /A3/F1 combination cannot be specified at the same time.
*8 In case that /PM1 is specified, /A4, /M1, /R1 cannot be specified together.
  And combination of /A2/F1 and /A3/TPS4 cannot be specified together.
*9 /MC1 can be specified for only MV2010, MV2020, MV2030, MV2040 and MV2048.
*10 "P" (EK standard) can be specified for only the 12 VDC.
*11 "Q" (PSB standard) can be specified for only the 12 VDC.
 

Standard accessories

Model Qty,
DAQSTANDARD 1
Terminal Screw 5
Instruction manual (First step guide: by paper) 1
Instruction manual (Main unit/commuication/DAQSTANDARD:CD-ROM) 1
128 MB CF CARD 1
Power cord 1 *1
AC adapter + Power cord 1 *2
*1 100VAC/240VAC Power supply (When the “-1” Power supply specification code is specified)
*2 12VDC Power supply (When specified the “-2” Power supply specification code) or Rechargeable battery (When specified the "-3" Power supply specification code).
 

Application software

Model Description OS
DXA120 DAQSTANDARD Windows 2000, XP, Vista
 
  for inquiries
     