Weight and dimensions

MV1000 외형도:

 

 

189 (W)×177 (H)×259 (D)

MV1000 weight:

Approx. 3.5 kg (MV1024)

MV2000 외형도:

307(W) x 273(H) x 260(D)

MV2000 weight:

Approx. 5.6 kg (MV2048)

 

Input components

Number of inputs:

MV1000: 4, 6, 8, 12, or 24 channels
MV2000: 8, 10, 20, 30, 40 or 48 channels

Measurement intervals:

MV1004, MV1008, MV2008: 125 ms, 250 ms, or 25ms in High-Speed mode
MV1006, MV1012, MV1024, MV2010, MV2020, MV2030, MV2040, MV2048: 1 s (100 ms not possible for A/D integra tion time), 2 s, 5 s,or 125 ms in High-Speed mode * A/D integration time is fixed at 1.67 ms in High-Speed mode

Points to consider when using High-Speed mode:

When using High-Speed mode (an A/D integration time of 1.67 ms) with the MVAdvanced, power supply noise and other factors may cause the measured values to fluctuate. If this is the case, then measure using Normal mode (an A/D integration time of 16.7 ms, 20 ms, or 100 ms).

Input types:

DCV (DC voltage: 20, 60, 200 mV, 2, 6, 20, 50 V, 1-5 V)
TC (thermocouple type: R, S, B, K, E, J, T, N, W, L,U,WRe)
RTD (resistance temperature detector: Pt100, JPt100)
DI (at the contact input or the TTL level)
DCA (DC current; with external shunt resistor)

 

Measuring range, measurement accuracy, and display resolution by typical input type

Input Range Measurement accuracy
(when the integration time is
16.7 ms or more)
Display resolution
DCV

1-5V

±(0.05% of rdg + 3digits) 1mV
Thermocouple* K ±(0.15% of rdg + 0.7℃) 0.1℃
Resistance thermometer detector Pt100 ±(0.15% of rdg + 0.3℃) 0.1℃

* Does not include the accuracy of reference junction compensation

 

Display

Display device:

MV1000: 5.5-inch TFT color LCD (320×240 dots)
MV2000: 10.4-inch TFT color LCD (640×480 dots)
Note:The LCD may contain some pixels that are always lighted or that never light, and variations in brightness may occur due to the characteristics of liquid crystals. Please note that these are not defects.

Display groups:

Number of display groups:
MV1000: 10 groups, MV2000: 36 groups
Maximum number of channels assignable per group:
MV1000: 6 channels, MV2000: 10 channels

Displayed colors:

Trend/bar graph display: 24 available colors
Background: White or black

Trend 화면:

Display types: Vertical, horizontal, horizontal wide,separated horizontal.

Bar 그래프 화면:

Direction: Vertical or horizontal

Digital 화면:

Update rate: 1 s

Overview 화면:

Channel number: Displays a list of all measurement and MATH channels along with their alarm states. Information display: Alarm Summary display, Message Summary display, Memory Summary display, Report display, Relay Condition display, Modbus Condition display

Log display:

Log display content: Log-in log, Error log, Trans-mission log, FTP log, Web log, E-mail log, SNTP log, DHCP log, Modbus log

Tag display:

Max. displayable characters: 16
Displayable characters: Alphanumeric characters

Message display:

Max. displayable characters: 32
Displayable characters: Alphanumeric characters
Historical display function: Allows for the display of data stored to internal or external memory.

LCD screen saver function:

You can to dim or turn OFF the LCD backlight if there are no keystrokes for a set time (1, 2, 5, 10, 30 min, or 1 hour).

Display screen registration function:

You can assign a name to a display screen and register it.
Max. registered screens: 8

 

Memory features

External media:

Media: Compact Flash (CF) card

Internal memory:

Media: Flash memory
Memory size: 80 MB or 200 MB (selected when purchasing)

Sample time:

 

Examples of internal memory sample times (with the MV1012 recording only event data files for 12 measuring channels and no calculation channels).


Save interval 125 ms 1 s 5 s 10 s 60 s 120 s
Sample time
(with 200 MB of memory)
Approx. 217 hours Approx.
72 days
Approx.
362 days.
Approx.
723 days
Approx.
12.1 years
Approx.
24 years
Sample time
(with 80 MB of memory)
Approx.
86 hours
Approx.
28 days
Approx.
144 days
Approx.
289 days
Approx.
4.8 years
Approx.
9.6 years
 

Max. savable data files:

400 (savable display data files and event data files combined)

Manual save:

Saves data files to the internal memory manually.You can save all data or only selected data. Destination drive: CF card or USB memory (if equipped with the USB option)

Auto save:

Save displayed data: Saves data to the CF card at a set interval. Save event data: Saves data to the CF card at a set interval (in Free Trigger mode) Save when finished sampling (when setting the trigger)

Data formats:

When saving to external media, both event data and display data can be saved in either binary or text format (data is always stored to internal memory in bi-nary format).

Sampling interval:

Display data: Varies according to the waveform update rate
Event data: User-set

Manual sample data:

You can choose when to save measurement/MATH channel data files to the internal memory or to a CF card.

Report data (only available if the unit is equipped with the calculation option):

Saves calculation results as data files to a CF card at the set times.

Types:

Hourly, daily, hourly + daily, daily + weekly, daily + monthly

Trigger function

Data can be saved using Free mode or Trigger mode. When using Trigger mode, the user must set the data length, pre-trigger, and trigger source.

Snapshot function:

Saves the displayed screen image data to a CF card.

Data file loading:

Data files saved to a CF card or to USB memory (if equipped with the USB option) can be loaded and displayed. Loading and saving setup data: Settings data can be saved and loaded in binary format.

USB interface:

USB specification 1.1 host

Ports:

2 (front and back)

Connectable devices:

Keyboards: 104 keyboards (US) compliant with USB HID Class Version 1.1
109 keyboards (Japanese)
External media: USB memory (not all types of USB memory are guaranteed to work)

 

Alarm functions

Alarms settable per channel:

4

Alarm types:

High/low limit, delay high/low limit, difference high/low limit, high/low limit on rate of change

Delay alarm time:

Can be set according to channel (cannot be set according to level) Range: 1 to 3600 seconds

Time intervals for the rate-of-change alarm:

A factor of 1 to 32 times the measurement interval (applies to all channels)

Display:

When an alarm occurs, the state (the alarm type) or common alarm state appears on the digital display

 

Event action function

Description:

A set action occurs in response to a set event.
Functions
Settable event actions: 40

 

Security function

Description:

You can customize key lock and login security functions for any transmission or keyboard command.

Key Lock:

Sets a password-protected key lock on all command keys and FUNC screen operations.

Login:

Limits access to the MVAdvanced with a login that prompts for username and password.

Security levels and user numbers:

System administrators: 5
General users: 30

 

Clock function

Clock:

Comes with a calendar function (for the western calendar)

Clock accuracy:

±10 ppm (does not include the less than one second delay that occurs when turning the power on)

 

Communication function (Ethernet)

Electrical specifications:

IEEE 802.3 compliant (DIX frame)

Transmission media:

Ethernet (10BASE-T)

Protocols implemented:

TCP, UDP, IP, ICMP, ARP, DHCP, HTTP, FTP, SMTP,SNTP, Modbus, and MV dedicated protocol

E-mail transmission functions
(E-mail client):

Automatically sends an e-mail in response to alarms and other events.

FTP client functions:

Automatically sends data files to an FTP server Transmittable files: Display data files, event data files, report data files, screen snapshot data files

FTP server functions:

Can transfer and delete files, manipulate directories, and produce file lists remotely from a network computer.

Web server function:

Displays MV screen images on a Web browser.

SNTP client function:

Queries a specified SNTP server for the time and synchronizes with it.
Time query methods: Set interval, start of memory sample, manual

SNTP server function:

Transmits the MV time settings via SNTP protocol.

DHCP client function:

Automatically retrieves the network address settings from a DHCP server.
Information retrieved automatically:
IP address, subnet mask, default gateway, DNS information

Modbus client function:

 

Loads data from other devices using Modbus protocol.*
*The calculation option (/M1) or the external input
channel option (/MC1) is required to load data.

Modbus server function:

 

Data can be read from the MV using the Modbus protocol.

 

Batch function

Description:

Allows for data display, data management, text field functions, and batch comment input using batches.

 

Power supply

AC power supply:

Rated supply voltage: 100 to 264 VAC (auto switching)

DC power supply:

Rated supply voltage: 12 VDC/24 VDC

AC power supply:

Operating supply voltage range: 90 to 132, 180 to 264 VAC

DC power supply:

Operating supply voltage range: 10.0 to 28.8 VDC

 

Power consumption

MV1000 power consumption

Supply voltage With LCD screen saver on Normal use Maximum
100 VAC

15 VA

30 VA

45 VA

240 VAC

25 VA

40 VA

60 VA

12 VDC

7 VA

14 VA

24 VA

 

MV2000 power consumption

Supply voltage With LCD screen saver on Normal use Maximum
100 VAC

28 VA

40 VA

65 VA

240 VAC

38 VA

54 VA

90 VA

12 VDC

9 VA

18 VA

35 VA

 
 

Rechargeable battery drive (MV1000 only):

Powered by a dedicated AC adapter or the dedicated Ni-MH battery pack.
The dedicated Ni-MH battery pack can only be charged when connected to the main unit.
If both the AC adapter and battery pack are connected, the AC adapter will be used.

Continuous operation time:

13 hours maximum (room temperature) under the following conditions: No USB connection; no option terminals; LCD backlight saver: OFF; transition time: 1 minute; external media saving: Auto-save.
Continuous operation time differs according to various conditions.

Normal operating conditions

Supply voltage:

AC power supply: 90 to 132, 180 to 250 VAC
DC power supply: 10.0 to 28.8 VDC

Supply frequency:

50 Hz±2%, 60 Hz±2%

Ambient temperature:

0 to 40°C (10 to 40°C with the battery model)

Ambient humidity:

20 to 80% RH (at 5 to 40°)

 

Optional specifications

● Alarm output relays (/A1, /A2, /A3, /A4)

Activates the relay output on the rear panel when an alarm occurs

Output points:

Choose from 2, 4, 6, or 12*
* Only with the MV2000
Not installable on the MV1008 or MV1024

 

●시리얼 통신(/C2, /C3)

Media:

EIA RS-232 (/C2) and RS-422/485 (four-wire) (/C3) compatible

Protocols implemented:

The dedicated protocol and the Modbus (master/slave) protocol

Settings/measurement server functions:

Using the dedicated protocol, the following functions are available
Settings and commands equivalent to the unit’s key commands.
Data output

Modbus master/slave functions:

Loads data from other devices using Modbus protocol.*
* The calculation option (/M1) or the external input channel option (/MC1) is required to load data

 

● Fail/status output relay (/F1)

Activates a relay output upon the detection of a CPU abnormality on the MV or a set condition.

 

● Calculation functions (/M1)

Performs calculations as well as displays and records the trends or numeric values of calculation channels listed below.

Max. calculation channels:

 

MV1004, MV1008: 12 channels
MV1006, MV1012, MV1024: 24 channels
MV2008: 12 channels
MV2010, MV2020, MV2030, MV2040, MV2048: 60 channels

Max. equation length:

120 characters

Calculation types:

General calculations: Basic arithmetic, square root, absolute value, common logarithm, natural logarithm, exponent, power, relational operations (<,≤, >, ≥, =,≠), logical operations (AND, OR, NOT, XOR) Statistical calculations: TLOG (maximum value, minimum value, average value, integrated value, and P-P value for time series data) CLOG (maximum value, minimum value, average value, integrated value, and P-P value for a set channel) Special calculations: PRE, HOLD(a):b, RESET(a):b, CARRY(a):b Conditional statement: [a?b:c]
Max. settable constants: 60 (K01 to K60)

Report function:

Report types: Hourly, daily, hourly + daily, daily + weekly, daily + monthly
Calculation types: Reports can be calculated using a combination of up to four of the following: Average, maximum value, minimum value, integrated value, and instantaneous value.

 

● Cu10/Cu25 RTD input/3-wire isolated RTD input (/N1)

Enables the use of Cu10 and Cu25 inputs in addition to the standard inputs.

 

● 3-wire isolated RTD input (/N2)All RTD (resistance thermometer detector) terminals

(A, B, and b) are isolated.
Note: Only available with the MV1006, MV1012,
MV2010, MV2020, MV2030, MV2040, and MV2048

 

● External input (/N3)

Enables the use of the following thermocouples and RTDs in addition to the standard inputs. TC: Kp vs Au7Fe, PLATINEL, PR40-20, NiNiMo, W/Wre26, TypeN(AWG14)
RTD: Pt25, Pt50, Ni100(SAMA), Ni100(DIN), Ni120,
J263*B, Cu53, Cu100

 

● Remote control (/R1)

The MV can be controlled through contact input (up to 8 inputs can be set).
24 VDC transmitter power supply (/TPS2*, /TPS4*)

Output voltage:

22.8 to 25.2 VDC (for rated current load)

Rated output current:

4 to 20 mADC

Maximum output current:

25 mADC (overcurrent protection level: approximately 68 mADC)
* /TPS2 is only available for the MV1000, /TPS4 is only available for the MV 2000

 

● Pulse input (/PM1)

Contact and open-collector pulse input is possible through the use of special remote input terminals. The calculation functions (/M1) and remote control (R1) options are included in the pulse input option. Number of Inputs: 3 channels (however, if the remote control input terminals are used for pulse input, then up to 8 channels can be made available)
Input methods: Photocoupler isolation (no isolation between channels)
Internal isolated power supply (approx. 5 V)
Input types: Dry contact, open collector (TTL or transistor)

 

● Input value correction (/CC1)

Ten-segment linearizer approximation can be used on every measurement channel to correct input values.
Settable broken-line points: 2 to 16

 

● Channel expansion (/MC1, only available on the MV2000)

You can use the Modbus master function to load data from other devices, and set data through the use of communication input commands. Additional channels are provided for communication input.
Note 1: Only available with the MV2010, MV2020, MV2030, MV2040, and MV2048
Note 2: When equipped with the external input channel option, the High-Speed mode measurement interval is unavailable.
Number of external input channels: 240 channels
(channel numbers 201 to 440)

 